Leave Your Message
UL/FM Approved Red Painted Fire Sprinkler Steel Pipe from China Suppliers - Premium Quality Factory Products
Hot Products

UL/FM Approved Red Painted Fire Sprinkler Steel Pipe from China Suppliers - Premium Quality Factory Products

As a leading China manufacturer and supplier of fire sprinkler steel pipes, our products are integral components of automatic fire suppression systems. Designed specifically for the transportation of water and effective fire-fighting agents, our steel pipes are built to meet rigorous global fire safety standards. To enhance their durability, each pipe is coated with a highly visible red epoxy or is hot-dip galvanized, significantly improving corrosion resistance.

By partnering with our factory, you can ensure reliable performance and compliance with essential safety regulations during fire emergencies.

Quick Details Table

Parameter

Details

Product Name

Fire Sprinkler Steel Pipe

Standard

ASTM A795, ASTM A53, ASTM A135, UL 852, FM 1630

Surface Finish

Red Epoxy Coated, Hot-Dip Galvanized

Connection Type

Grooved, NPT / BSP Threaded, Welded

Size Range

DN15 - DN300 (1/2 - 12)

    Detailed Description of Fire Sprinkler Steel Pipe

    Fire sprinkler steel pipes are intended for automatic fire sprinkler systems. The primary purpose of these pipes is to automatically activate in the initial stages of a fire, discharging water uniformly across the given protected location to either contain or extinguish the fire. Our fire sprinkler pipes are mainly manufactured of quality carbon steel (Q235B) as the base metal, and manufactured by the (electric resistance welded) ERW process to production uniformity in the weld and high pressure resistance.

    Two Main Surface Treatment Options Available

    Corrosion protection of steel pipes is crucial in fire suppression systems because they usually have stagnant lines filled with water. We offer two main types of external surface treatment: red epoxy coating and hot dipped galvanizing. Firstly, the red epoxy coating offers good corrosion resistance and easy identification within complex systems. Secondly, the hot dipped galvanizing creates a layer of zinc-iron alloy on both the outside and inside of the pipe to combat corrosion, offering robust and long term protection against corrosion and is a good option for dry pipe and pre-action systems, (especially in corrosive environments).

    Key Parameters

    Parameter

    Details

    Base Pipe Type

    ERW Welded Steel Pipe

    Executive Standards

    ASTM A795, ASTM A53, ASTM A135, UL 852, FM 1630, GB/T 3091

    Steel Grade

    Gr.A, Gr.B, Q235B, Q345B

    Size Range (NPS)

    DN15 - DN300 (1/2" - 12")

    Wall Thickness

    Schedule 10, Schedule 40 (or as per standard requirements)

    Length

    Usually 5.8m, 6m, 11.8m, 12m, customizable

    Connection Type

    Grooved, Threaded, Welded

    Surface Treatment

    Red Epoxy Coated (Internal/External), Hot-Dip Galvanized, Black Painted, Bare

    Certifications

    UL Listed, FM Approved, CE Certified, etc.

    Frequently Asked Questions

    Q What manufacturing process is used for fire sprinkler steel pipes?
    Our fire sprinkler steel pipes are manufactured using the Electric Resistance Welding (ERW) process. This method ensures uniform weld quality and high pressure resistance, making the pipes reliable and consistent for use in automatic fire sprinkler systems.
    Q What standards do your fire sprinkler steel pipes comply with?
    Our fire sprinkler steel pipes comply with multiple internationally recognized standards, including ASTM A795, ASTM A53, ASTM A135, UL 852, FM 1630, and GB/T 3091. They are also UL Listed, FM Approved, and CE Certified to meet global project requirements.
    Q What is the difference between red epoxy coating and hot-dip galvanizing?
    Red epoxy coating provides good corrosion resistance and makes the pipes easy to identify within complex fire suppression systems. Hot-dip galvanizing forms a zinc-iron alloy layer on both the internal and external surfaces, offering stronger, longer-lasting protection — especially suited for dry pipe and pre-action systems in corrosive environments.
    Q What size range is available for fire sprinkler steel pipes?
    We supply fire sprinkler steel pipes in a size range of DN15 to DN300, equivalent to 1/2" to 12" NPS. Wall thickness options include Schedule 10 and Schedule 40, or as specified by relevant standard requirements.
    Q What connection types are available for these pipes?
    Fire sprinkler steel pipes are available with three main connection types: Grooved, Threaded, and Welded. The choice of connection depends on the specific system design, installation requirements, and applicable fire protection standards.
    Q Can the pipe length be customized?
    Yes. Standard pipe lengths are 5.8m, 6m, 11.8m, and 12m. However, we also offer customizable lengths to accommodate specific project needs. Please contact us with your requirements for a tailored solution.