Leave Your Message
UL/FM Approved Red Painted Fire Sprinkler Steel Pipe
Anti Corrosion Steel Pipe

UL/FM Approved Red Painted Fire Sprinkler Steel Pipe

  • quality (2)

    UL/FM Approved

  • quality (1)

    Excellent Corrosion Resistance

  • quality (3)

    Easy Installation

The steel pipe used in fire sprinklers is an essential part of an automatic fire suppression system, intended for transporting water or specific fire-fighting agents. Its exterior is usually coated with a red epoxy or hot-dip galvanized to improve resistance to corrosion and make it easily recognizable. This product is produced in accordance with global fire safety regulations, guaranteeing dependable and effective performance in case of a fire emergency.

Quick Details Table

Parameter

Details

Product Name

Fire Sprinkler Steel Pipe

Standard

ASTM A795, ASTM A53, ASTM A135, UL 852, FM 1630

Surface Finish

Red Epoxy Coated, Hot-Dip Galvanized

Connection Type

Grooved, NPT / BSP Threaded, Welded

Size Range

DN15 - DN300 (1/2" - 12")

    Detailed Description of Fire Sprinkler Steel Pipe

    Fire sprinkler steel pipes are intended for automatic fire sprinkler systems. The primary purpose of these pipes is to automatically activate in the initial stages of a fire, discharging water uniformly across the given protected location to either contain or extinguish the fire. Our fire sprinkler pipes are mainly manufactured of quality carbon steel (Q235B) as the base metal, and manufactured by the (electric resistance welded) ERW process to production uniformity in the weld and high pressure resistance.

    Corrosion protection of steel pipes is crucial in fire suppression systems because they usually have stagnant lines filled with water. We offer two main types of external surface treatment: red epoxy coating and hot dipped galvanizing. Firstly, the red epoxy coating offers good corrosion resistance and easy identification within complex systems. Secondly, the hot dipped galvanizing creates a layer of zinc-iron alloy on both the outside and inside of the pipe to combat corrosion, offering robust and long term protection against corrosion and is a good option for dry pipe and pre-action systems, (especially in corrosive environments).

    Key Parameters

    Parameter

    Details

    Base Pipe Type

    ERW Welded Steel Pipe

    Executive Standards

    ASTM A795, ASTM A53, ASTM A135, UL 852, FM 1630, GB/T 3091

    Steel Grade

    Gr.A, Gr.B, Q235B, Q345B

    Size Range (NPS)

    DN15 - DN300 (1/2" - 12")

    Wall Thickness

    Schedule 10, Schedule 40 (or as per standard requirements)

    Length

    Usually 5.8m, 6m, 11.8m, 12m, customizable

    Connection Type

    Grooved, Threaded, Welded

    Surface Treatment

    Red Epoxy Coated (Internal/External), Hot-Dip Galvanized, Black Painted, Bare

    Certifications

    UL Listed, FM Approved, CE Certified, etc.

    Fire Sprinkler Pipe Specification (ASTM A795)

    ASTM A53

    OD(in/mm)

    WT(mm)

    Size

    Inch

    mm

    SCH10

    SCH20

    SCH40

    SCH80

    DN15

    1

    21.3

    -

    -

    2.77

    3.73

    DN20

    3

    26.7

    -

    -

    2.87

    3.91

    DN25

    1"

    33.4

    -

    -

    3.38

    4.55

    DN32

    2004/1/1

    42.2

    -

    -

    3.56

    4.85

    DN40

    2002/1/1

    48.3

    -

    -

    3.68

    5.05

    DN50

    2"

    60.3

    -

    -

    3.91

    5.54

    DN65

    2002/2/1

    73

    -

    -

    5.16

    7.01

    DN80

    3"

    88.9

    -

    -

    5.49

    7.62

    DN90

    2002/3/1

    101.6

    -

    -

    5.74

    8.08

    DN100

    4"

    114.3

    -

    -

    6.02

    8.58

    DN125

    5"

    141.3

    -

    -

    6.55

    9.53

    DN150

    6"

    168.3

    -

    -

    7.11

    10.97

    DN200

    8"

    219.1

    -

    6.35

    8.18

    12.7

    DN250

    10"

    273.1

    -

    6.35

    9.27

    15.09

    DN300

    12"

    323.9

    -

    6.35

    10.31

    17.48

    DN350

    14"

    355.5

    6.35

    7.92

    11.13

    19.05

    DN400

    16"

    406.4

    6.35

    7.92

    12.7

    21.44

    DN450

    18"

    457.2

    6.35

    7.92

    14.27

    23.83

    DN500

    20"

    508

    6.35

    9.53

    15.09

    26.19

    DN550

    22"

    558.8

    6.35

    9.53

    -

    28.58

    DN600

    24"

    609.6

    6.35

    9.53

    17.48

    30.96

    DN650

    26"

    660.4

    7.92

    12.7

    -

    -

    DN700

    28"

    711.6

    7.92

    12.7

    -

    -

    DN750

    30"

    762

    7.92

    12.7

    -

    -

    DN800

    32"

    812.8

    7.92

    12.7

    17.48

    -

    DN850

    34"

    863.6

    7.92

    12.7

    17.48

    -

    DN900

    36"

    914.4

    7.92

    12.7

    19.05

    -

     

    ASTM A795

    DN

    Schedule 10

    Schedule 30/40

    Schedule 10

    Schedule 30/40

    OD(in./mm)

    NWT(in./mm)

    1/2

    -

    -

    0.840

    21.3

    -

    -

    0.109

    2.77

    3/4

    1.050

    26.7

    1.050

    26.7

    0.08

    2.11

    0.113

    2.87

    1

    1.315

    33.4

    1.315

    33.4

    0.109

    2.77

    0.133

    3.38

    11/4

    1.660

    42.1

    1.660

    42.1

    0.109

    2.77

    0.14

    3.56

    11/2

    1.900

    48.3

    1.900

    48.3

    0.109

    2.77

    0.145

    3.68

    2

    2.375

    60.3

    2.375

    60.3

    0.109

    2.77

    0.154

    3.91

    21/2

    2.875

    73

    2.875

    73

    0.12

    3.05

    0.203

    5.16

    3

    3.500

    88.9

    3.500

    88.9

    0.12

    3.05

    0.216

    5.49

    31/2

    4.000

    101.6

    4.000

    101.6

    0.12

    3.05

    0.226

    5.74

    4

    4.500

    114.3

    4.500

    114.3

    0.12

    3.05

    0.237

    6.02

    5

    5.563

    141.3

    5.563

    141.3

    0.134

    3.4

    0.258

    6.55

    6

    6.625

    168.3

    6.625

    168.3

    0.134

    3.4

    0.28

    7.11

    8

    8.625

    219.1

    8.625

    219.1

    0.188C

    4.8

    0.277C

    7.04

    10

    10.750

    273

    10.750

    273

    0.188C

    4.8

    0.277C

    7.8

     

    Main Application Areas

    Steel pipe is the key piping material for many types of automatic fire sprinkler systems used worldwide like:

    ● Wet Pipe System: The most common type of automatic fire sprinkler system. In wet pipe systems, the pipes are always filled with pressurized water. These systems can be used where ambient temperatures remain above 4°C. Applications in this area include office buildings (+4°C), dry warehouse storage, hotels malls, etc.

    ● Dry Pipe System: Dry pipe systems have pipes filled with compressed air or nitrogen and water enters the pipes after activation of the sprinkler head. Dry pipe systems can be used in areas like parking garages, unconditioned spaces, or cool storage areas at or below freezing.

    ● Pre-action system: A pre-action system is a combination of fire detection and sprinkler systems as it requires activation of the missing piece, with both an appropriate detector and a qualified sprinkler head to release water into the pipes. The pre-action systems are intended for high value and sensitive areas that do not have water damage opportunities, like data centers, library's and archives.

    ● Deluge system: In a deluge system all of the sprinkler heads are open. An independent fire detection system activates a valve that allows a large volume of water to be released from all of the sprinkler heads at the same time- load and unload or sprinkler to wall location. They are used in areas with the potential for very rapid spread of fire, like chemical plants and aircraft hangars.

    ● Water curtain system: Used to accomplish either cooling protection for people or things from the fires radiant heat or to create fire-resistant barriers.

    Advantages of Sprinkler Steel Pipe

     High Reliability: Rigorously manufactured to international fire protection standards and passed water pressure testing to guarantee adequate water supply (no leaks and high pressure-bearing capability).

    Excellent corrosion resistance: professional coated or galvanization treatment considerably improves pipe service life performance in wet environment.

    Fast and easy installation: The trench connection has a significantly decreased construction schedule and doesn’t require on-site welding, which minimizes installation costs and reduces fire risks.

    Strong system compatibility: Compatible with most standard sprinkler heads, valves and fittings.

    Clearly Recognizable: The unique red coating makes it easily recognizable as fire protection piping in building piping systems.

    Leave Your Message